Steam at Lower Cost and Emissions than Traditional Boilers
The Skyven Arcturus Steam-Generating Heat Pump
The Arcturus line of industrial steam-generating heat pumps recovers low-temperature heat and upgrades it into boiler-quality, emissions-free industrial steam. It generates steam at up to 9x the efficiency of a traditional boiler, significantly lowering steam costs.

Key Benefits
Lower Steam Costs
Uses up to 90% less input energy than traditional boilers, reducing steam costs.
Increased Reliability
Supplies baseload steam, with pre-existing boilers retained for backup and peak demand.
Fuel Flexibility
Minimizes energy costs by shifting to boilers when real-time electricity prices are high.

The Technology
How Arcturus Works
Arcturus uses electricity and recovered heat to generate boiler-quality, emissions-free industrial steam. It captures low-temperature heat from onsite sources like humid exhaust and process cooling and transfers that heat to a water loop. The heated water is then flashed under vacuum to produce low-pressure steam, which passes through a multi-stage compressor train that raises it to the temperature and pressure required by steam-consuming processes at the facility.
Arcturus produces temperature lifts from 38°C to 185°C, with corresponding COPs ranging from 8.0 down to 2.0, compared to less than one for a gas-fired boiler. Each Arcturus system is configured around the hottest heat source and lowest steam pressure available at the site, minimizing lift to maximize COP and cost savings.
- Steam Temperature: Up to 215°C / 420°F
- Steam Pressure: Up to 20.7 barg / 300 psig
- System Capacity: 10-100 tons of steam per hour
- Heat Source Temperature: As low as 30°C / 86°F
- Coefficient of Performance (COP): Between 2.0 and 8.0, depending on site conditions
- Refrigerant & Working Fluid: Water (non-toxic, inexpensive, zero GWP)
Best of Both Worlds
High Performance, Standardized Design
Industrial heat pumps have generally forced a choice: high performance or low cost. Achieving high performance typically means one-off custom engineering with high cost, complexity, and long lead times. On the other hand, lower cost typically means sacrificing COP and lift in favor of standardization.
Arcturus provides the best of both worlds. Every system is configured from a library of standardized, modularized subsystems, arranged to maximize COP and lift while keeping costs low.

Built for Flexibility
Redundant, Hybrid Configuration
Arcturus connects in parallel with existing steam generation systems, adding steam capacity without requiring boiler replacement. The result is two independent sources of steam, one electric and one fuel-fired, with the ability to switch between them as energy costs fluctuate throughout the day.
- No Downtime: Redundant, bypassable integration ensures no impact to operations during installation or maintenance.
- Increased Reliability: Supplies baseload steam, while existing boilers remain available for backup and peak demand.
- Fuel Flexibility: Controls monitor electricity and natural gas rates in real time and shift steam generation between the two within minutes as prices change.
Explore Arcturus COP
Coefficient of Performance (COP) is an expression of efficiency and varies as a function of heat source temperature, steam output pressure, and temperature lift. Higher COP means less electricity required and lower steam costs.
Arcturus achieves COPs approximately 50% higher than closed-cycle heat pumps at any given temperature lift due to its multi-stage, open-cycle architecture and direct compression of water.
The interactive chart below allows you to explore Arcturus COPs at various heat source temperatures and steam outputs.
Skyven Arcturus — COP Explorer
Coefficient of performance across heat source temperatures and steam delivery pressures
Explore Arcturus Projects Across Industries
Pulp & Paper
Recycled paper facility
in Western Europe
Annual Natural Gas Usage:
663,239 MWh
(2,256,147 MMBtu)
Waste Heat Source:
Paper Machine Exhaust
With Skyven Arcturus:
-
Annual OpEx Savings
€3,235,480
(Excluding capital recovery)
-
CapEx to Customer under EaaS
€0
-
Coefficient of Performance (COP)
3.1
-
Annual Emissions Avoided
63,925 tonnes CO₂
Chemicals
Integrated petrochemical
plant in Western Europe
Annual Natural Gas Usage:
856,418 MWh
(2,913,284 MMBtu)
Waste Heat Source:
Column Condenser
With Skyven Arcturus:
-
Annual OpEx Savings
€5,995,320
(Excluding capital recovery)
-
CapEx to Customer under EaaS
€0
-
Coefficient of Performance (COP)
3.6
-
Annual Emissions Avoided
37,682 tonnes CO₂
Food & Beverage
Snack food manufacturing plant
in the Western United States
Annual Natural Gas Usage:
148,465 MWh
(505,036 MMBtu)
Waste Heat Source:
Oven and Fryer Exhaust
With Skyven Arcturus:
-
Annual OpEx Savings
€1,421,936
(Excluding capital recovery)
-
CapEx to Customer under EaaS
€0
-
Coefficient of Performance (COP)
2.8
-
Annual Emissions Avoided
15,435 tonnes CO₂
Ethanol
Ethanol facility in the
Northeastern United States
Annual Natural Gas Usage:
468,855 MWh
(1,594,098 MMBtu)
Waste Heat Source:
Dryer Exhaust
With Skyven Arcturus:
-
Annual OpEx Savings
€1,193,487
(Excluding capital recovery)
-
CapEx to Customer under EaaS
€0
-
Coefficient of Performance (COP)
7.6
-
Annual Emissions Avoided
18,580 tonnes CO₂
The best industrial heat pump works within the realities of an operating plant. Arcturus lowers steam costs while maintaining the reliability manufacturers depend on.
Julian Parra
Head of Process Engineering, Skyven Technologies
Let’s Start the Conversation
Let’s Start the Conversation
Share a few details about your facility, and we’ll be in touch regarding next steps for an Arcturus project at your site.
NETHERLANDS
Prof. van Weliestraat 12
6524 NN Nijmegen
BELGIUM
Anselmostraat 66
2018 Antwerp
TEXAS (HQ)
4440 Spring Valley Rd
Farmers Branch, TX 75244
CALIFORNIA
5370 North Chestnut Avenue
M/S OF 18
Fresno, CA 93740